Sign In | Join Free | My chinalane.org
China PEAK Instruments (Shanghai) Co., Ltd. logo
PEAK Instruments (Shanghai) Co., Ltd.
PEAK Instruments (Shanghai) Co., Ltd.
Verified Supplier

1 Years

Home > UV Visible Spectrophotometer >

1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range

PEAK Instruments (Shanghai) Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range

Warranty : 3 years

Customized support : OEM, ODM

Place of Origin : Shanghai, China

Brand Name : PEAK INSTRUMENTS

Model Number : C-7200S

Size : 61*46*24CM

Weight : 23KG

Focal Length : Null

Wavelength Range : 190-1100nm

Display : 7 inch LCD screen

Optical System : Double beam, Holographic Grating (1200 Lines/mm)

Spectral Bandwidth : 1nm

Wavelength Accuracy : 0.3nm

Wavelength Repeatability : ≤0.2nm

Stray light : ≤0.05%T@220, 360nm

Baseline Flatness : 0.002A

Noise : 0.0003@500nm

Detector : Solid Silicon Photodiode

Light Source : Deuterium/Tungsten Lamp

Price : $3,445.00/units >=1 units

MOQ : 1 unit

Contact Now

Product Description
Product Name
Double beam 190-1100nm UV Visible 1nm Spectrophotometer
Origin
China
Brand
PEAK INSTRUMENTS
Model
C-7200S
Size
61*46*24CM
Weight
23KG
Wavelength range
190-1100nm
Display
7 inch LCD screen
Optical System
Double beam, Holographic Grating (1200 Lines/mm)
Spectral Bandwidth
2nm
Wavelength Accuracy
±0.3nm
Wavelength Repeatability
≤0.2nm
Stray Light
≤0.05%T@220, 360nm
Baseline Flatness
±0.002A
Noise
0.0003@500nm
Detector
Solid Silicon Photodiode
Light Source
Deuterium/Tungsten Lamp
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
1. Photometry Measurements
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
2. Quantitative Test
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
3. Kinetics Measurement(time scanning)
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
4. Wavelength Scanning
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
5. Multiwavelength Test
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
6. DNA/Protein measurement
Our Advantages
Quality
1. Our products have good quality and very positive reputations in the market.
2. Customers are very happy with them and have a lot of good comments about our intruments and service.
Delivery Time
1. We can get them ready 3-5 days after order confirmation for small orders.
2. For big quantities, need to be confirmed.
3. In most cases, fast delivery is guaranteed.
Technical Support
1. We have service manual. If not, detailed documents or videos will be provided.
2. We can provide online or site training in our factory.
3. We can have video conference at any time.
Aftersales Support
1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.
2. Within warranty, we will solve the problem for you with no charge(except for consumables).
3. You can call, text or email us at any time. We have good English speakers.
Warranty Time
One year and extendable
Our product advantages are as follws:
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
1. 7 inch color LCD screen(button models) can show more parameters
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
2. Silicone buttons with much longer life span and easier to be operated
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
2. 7 inch capacitive touch screen and user friendly interface
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
4. Standard USB ports for data transfer and PC software connection.
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
5. More functions for basic models
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
6. Stable system with microcomputer processing
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
7. Automatic 8 position 1 cm cell holder(optional)
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
8. Long path cell holder can holde 1-10cm cuvettes(optional)
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
9. Tube rack for tubes with 16mm diameters(optional for all models)
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
10. Film cell holder(optional for all models)
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
11. Automatic sampler/sipper system(optional)
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
12. PC software, thermal printer, etc.
Why Choose Us
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
1. Positive comments from our Italian client
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
2. Good review from our customer in Italy
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
3. Great comments from Syria client
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
4. UAE customer is satified with our pH meter
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
5. Argentina customer is happy with our pH meters
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
6. Turkey user is satisfied with its performance of spectrophotometer
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
7. Spain customer is very happy with our fast service and professional technical support
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
8. Indian client is happy with our great support
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
9. Peru customer likes our spectrophotometer very much
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
10. Salvador customer has good comments on our pH meter
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
11. South Africa customer is happy with the accuracy of our spectrophotometer and pH meter
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
12. Customer in Poland said our products are very good
Certifications
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range

CE

ISO 9001 and ISO14001 are also available
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range

CE ANNEX

Product process
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
1.Install main board
2.Connect the cables for main board
3.Install W1 lamp and D2 lamp
4.Assemble sample chamber and cell holder
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
5.Install power board
6.Assemble monochromator
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
7.Upload software
8.Adjust and test W1 lamp and D2 lamp
9.System test
10.Housing installation and final calibration
Customer Photos
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
Customer visit and training
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
Visit cutomers and have a training
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
Customer from Brazil
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
Visit and train customers in Chile
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
Training
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
Customer from Argentina
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
Clients from Korea
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
Distributor from Thailand
FAQ
Q: What areas and applications can it be used?
A: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.
Q: Does it need any installation
A: The installation is very simple, just need to connect it to power supply and turn it on, then you can use it.
Q: What standard accessories are included?
A: Main unit, 1cm cell holder(4 positions for single beam and 2 positions for double beam), 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), one USB with user manual and power cable.
Q: Is PC software included?
A: The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.
Q: Why the reading is red and reach its maximum value 3.00Abs?
A: Probably you use the glass cuvette in UV range.
Q: Why the wavelength calibration or self checking fail?
A: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.
Q: Why is the reading is not as accurate as before?
A: Do the wavelength calibration before testing or restore the device to its default factory settings.
Q: Why PC software can not be installed successfully?
A: Close your anti-virus software on the computer and do it again.
Q: Why the software can not be connected successfully?
A: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.
Q: Can the data transferred to USB or PC?
A: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.
Q: Why the Abs value is negative(lower than zero).
A: Do the blanking or change the reference sample.
Exhibition
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
Analytica in Germany
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
Pittcon in USA
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
ArabLab in Dubai
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
IndiaLabExpo in India
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
Analytica Lab Africa
1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range
Analitica Latin America in Sao Paulo, Brazil

Wholesale 1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range from china suppliers

1nm UV/VIS Spectrophotometer with Stray Light≤0.05%T 220 and 190-1100nm Wavelength Range Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: PEAK Instruments (Shanghai) Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)